Onset/offset characteristics and intubating conditions of rapacuronium: a comparison with rocuronium.
Br J Anaesth 85(2):246-50 (2000) PMID 10992833
We compared onset and offset of action and tracheal intubating conditions after rapacuronium and rocuronium in 60 patients in a randomized, assessor-blinded study. Following induction of anaesthesia with propofol 2.5 mg kg-1, either rapacuronium 1.5 mg kg-1 (n = 30) or rocuronium 0.6 mg kg-1 (n = 30) was administered to facilitate tracheal intubation. Anaesthesia was maintained with either a propofol infusion (100 micrograms kg-1 min-1) or sevoflurane (1% end-tidal) with 66% nitrous oxide (N2O), n = 15 in each subgroup. Neuromuscular monitoring was performed using an electromyographic (EMG) device (Datex Relaxograph). The lag times (mean 42 (SD 11) s and 44 (16) s), maximum block (99 (2)% and 98 (3)%) and intubating conditions at 60 s (good-to-excellent in 86% and 84% of patients) were similar for rapacuronium and rocuronium, respectively. The onset time of rapacuronium was shorter than rocuronium (87 (20) vs 141 (65) s, P < 0.001), and the degree of block at 60 s was greater (69 (26) vs 50 (27)%, P < 0.05). Twenty-five per cent recovery was shorter with rapacuronium than rocuronium during propofol (15.0 (3.2) vs 39.1 (14.2) min, P < 0.001) and sevoflurane (15.1 (4.2) vs 47.8 (19.0) min, P < 0.001) anaesthesia. We conclude that rapacuronium 1.5 mg kg-1 had a more rapid onset, similar intubating conditions, and shorter recovery times than rocuronium 0.6 mg kg-1.
DOI: 10.1093/bja/85.2.246
Version: za2963e q8za9 q8zbf q8zc0 q8zde q8ze6 q8zf5 q8zgb