Extracated human molars were used for the study, flat dentinal surfaces were prepared on the occlusal surfaces, and then 4th and 5th generation dentin bonding agents were used in dry and moist conditions to bond composite resin onto the flat dentin surfaces. Shear Bond Strength was measured using Instron Universal Testing machine. Failures were recorded as adhesive, cohesive and mixed. Bond strength was highest in moist condition, because the moist surface permits more porous collagen network and hence greater infiltration of adhesive monomers, than do surfaces that are air dried. Moreover, those dentin bonding agents whose primers are based on acetone show improved bond strength, because acetone aggressively pursues and displaces water in the substrate, resulting in the primer resin being carried into tissue channels and porosities. When the dentin is air dried, the water that is supporting the collagen network evaporates causing the collagen network to collapse network is greatly reduced, which in turn decreases the premeability of intertubular dentin to adhesive resin and as a result causes decrease in bond strength. 5th generation dentin bonding agent showed significant improvement in the moist dentin bond strength.

Version: za2963e q8zad q8zb2 q8zce q8zd5 q8ze8 q8zf0 q8zg4

Similar articles you may find interesting…

  1. Determination by LC-MS of Juvenile Hormone Titers in Hemolymph of the Silkworm, Bombyx mori.

    Biosci Biotechnol Biochem (2013) PMID 23649254

    I was observed immediately after ecdysis in the 3rd and 4th instar stages. The JH I titer sharply decreased on day 1 and reached the lowest level before ecdysis, but there was no peak at the beginning of the 5th stadium, and no apparent increase was observed until pupation....
  2. Graphene-hemin hybrid material as effective catalyst for selective oxidation of primary C-H bond in toluene.

    Sci Rep (2013) PMID 23648870

    An effective hemin catalyst on graphene support for selective oxidation of primary C-H bond in toluene is reported with an over 50% conversion rate achieved at mild conditions. Significantly this hybrid material shows catalytic efficiency in toluene oxidation with selectivity towards...
  3. Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment.

    Integr Biol (Camb) (2013) PMID 23644926

    We describe a microfluidic device lined by living human kidney epithelial cells exposed to fluidic flow that mimics key functions of the human kidney proximal tubule. Primary kidney epithelial cells isolated from human proximal tubule are cultured on the upper surface of an extracellular matrix-coat...