Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger.

Exp Physiol 90(4):437-46 (2005) PMID 15802289

In this paper we review recent developments in the methodology of non-invasive finger arterial pressure measurement and the information about arterial flow that can be obtained from it. Continuous measurement of finger pressure based on the volume-clamp method was introduced in the early 1980s both for research purposes and for clinical medicine. Finger pressure tracks intra-arterial pressure but the pressure waves may differ systematically both in shape and magnitude. Such bias can, at least partly, be circumvented by reconstruction of brachial pressure from finger pressure by using a general inverse anti-resonance model correcting for the difference in pressure waveforms and an individual forearm cuff calibration. The Modelflow method as implemented in the Finometer computes an aortic flow waveform from peripheral arterial pressure by simulating a non-linear three-element model of the aortic input impedance. The methodology tracks fast changes in stroke volume (SV) during various experimental protocols including postural stress and exercise. If absolute values are required, calibration against a gold standard is needed. Otherwise, Modelflow-measured SV is expressed as change from control with the same precision in tracking. Beat-to-beat information on arterial flow offers important and clinically relevant information on the circulation beyond what can be detected by arterial pressure.

Version: za2963e q8zac q8zb5 q8zc9 q8zdb q8ze6 q8zfc q8zgb

Similar articles you may find interesting…

  1. Study Protocol--accurate assessment of kidney function in Indigenous Australians: aims and methods of the eGFR study.

    BMC Public Health (2010) PMID 20167129

    We are able to measure accurately kidney function. Glomerular filtration rate is the best overall marker of kidney function. However, differences in body build and body composition between Indigenous and non-Indigenous Australians suggest that creatinine-based estimates of glomerular filtration rate...
  2. Effects of catecholamines on the pulmonary venous bed in sheep.

    Crit Care Med 26(9):1569-75 (1998) PMID 9751595

    A 7-Fr pulmonary artery catheter was placed in a proximal location to measure cardiac output and pressure in a large pulmonary vein (Ppw) after balloon inflation. Another catheter wedged in a small pulmonary artery measured pressure in a small pulmonary vein (Pdw). A third catheter measured left atr...
  3. WISE 2005: stroke volume changes contribute to the pressor response during ischemic handgrip exercise in women.

    J Appl Physiol 103(1):228-33 (2007) PMID 17412786