FEV6 as a surrogate for FVC in detecting airways obstruction and restriction in the workplace.

Eur Respir J 27(2):374-7 (2006) PMID 16452595

Compared with measurements of forced vital capacity (FVC), using the forced expiratory volume in six seconds (FEV(6)) reduces test time and frustration. It was hypothesised that using FEV(6) in the workplace setting would result in an acceptably low misclassification rate for detecting airways obstruction and spirometry-defined restriction when compared with using the traditional FVC. Experienced technicians from the National Institute for Occupational Safety and Health performed spirometry using dry rolling-seal spirometers as per American Thoracic Society guidelines in four workplace investigations. Airways obstruction was defined as an FEV(1)/FVC % below the lower limit of normal (LLN) using National Health and Nutrition Examination Survey III reference equations. Restriction was defined as an FVC below the LLN with a normal FEV(1)/FVC %. These "gold standard" definitions were compared with definitions based on FEV(6) (obstruction: FEV(1)/FEV(6) below the LLN; restriction: FEV(6) below the LLN with a normal FEV(1)/FEV(6)). The median (range) age of the 1,139 workers was 37 yrs (18-71 yrs) and 51.4% were male. A significantly high overall agreement was obtained between the two definitions. In conclusion, the current results confirm that forced expiratory volume in six seconds can be used as a surrogate for forced vital capacity in detecting airways obstruction and restriction in workers, although with some misclassification when compared to obtaining American Thoracic Society-acceptable manoeuvres of longer duration.

DOI: 10.1183/09031936.06.00081305
Version: za2963e q8za0 q8zb3 q8zce q8zd4 q8ze3 q8zfe q8zg1

Similar articles you may find interesting…

  1. Correcting Diacetyl Concentrations from Air Samples Collected with NIOSH Method 2557.

    J Occup Environ Hyg 8(2):59-70 (2011) PMID 21229454

  2. Therapeutic drug monitoring of digoxin: impact of endogenous and exogenous digoxin-like immunoreactive substances.

    Toxicol Rev 25(4):273-81 (2006) PMID 17288498

    Digoxin is a cardioactive drug with a narrow therapeutic range. Therapeutic drug monitoring is essential in clinical practice for efficacy as well as to avoid digoxin toxicity. Immunoassays are commonly used in clinical laboratories for determination of serum or plasma digoxin concentrations. Unfort...
  3. Exhaled nitric oxide measurement in workers in a microwave popcorn production plant.

    Int J Occup Environ Health 12(2):106-10 (2006) PMID 16722189

    Airways obstruction in microwave-popcorn workers has been attributed to inhalation of flavoring agents. Two former workers at a microwave-popcorn plant were found by lung biopsy to have bronchiolitis obliterans. The study's aim was to determine whether exhaled nitric oxide (FENO) levels were associa...