Rapid tracking of small displacements with ultrasound.

IEEE Trans Ultrason Ferroelectr Freq Con... 53(6):1103-17 (2006) PMID 16846143

Time-delay estimators, such as normalized cross correlation and phase-shift estimation, form the computational basis for elastography, blood flow measurements, and acoustic radiation force impulse (ARFI) imaging. This paper examines the performance of these algorithms for small displacements (less than half the ultrasound pulse wavelength). The effects of noise, bandwidth, stationary echoes, kernel size, downsampling, interpolation, and quadrature demodulation on the accuracy of the time delay estimates are measured in terms of bias and jitter. Particular attention is given to the accuracy and resolution of the displacement measurements and to the computational efficiency of the algorithms. In most cases, Loupas' two-dimensional (2-D) autocorrelator performs as well as the gold standard, normalized cross correlation. However, Loupas' algorithm's calculation time is significantly faster, and it is particularly suited to operate on the signal data format most commonly used in ultrasound scanners. These results are used to implement a real-time ARFI imaging system using a commercial ultrasound scanner and a computer cluster. Images processed with the algorithms are examined in an ex vivo liver ablation study.

Version: za2963e q8za3 q8zb4 q8zca q8zde q8ze0 q8zfd q8zg9

Similar articles you may find interesting…

  1. Characterization of clutter in ultrasonic imaging using a nonlinear full-wave simulation method and in vivo human tissue.

    J Acoust Soc Am 127(3):1866 (2010) PMID 20330567

    We have performed simulations of clutter using a nonlinear, full-wave method to demonstrate the characteristics and sources of ultrasonic clutter. Representations of human abdominal layers, created from histological stains of human abdominal layers, were placed at the surface of the transducer. Poin...
  2. A heterogeneous nonlinear attenuating full-wave model of ultrasound.

    IEEE Trans Ultrason Ferroelectr Freq Control 56(3):474-88 (2009) PMID 19411208

    We present a numerical solution of the relaxation attenuation laws that allows modeling of arbitrary frequency dependent attenuation, such as that observed in tissue. A perfectly matched layer (PML) is implemented at the boundaries with a numerical implementation that allows the PML to be used with...
  3. Optical tracking of acoustic radiation force impulse-induced dynamics in a tissue-mimicking phantom.

    J Acoust Soc Am 126(5):2733-45 (2009) PMID 19894849

    Optical tracking was utilized to investigate the acoustic radiation force impulse (ARFI)-induced response, generated by a 5-MHz piston transducer, in a translucent tissue-mimicking phantom. Suspended 10-mum microspheres were tracked axially and laterally at multiple locations through...