Advanced search×

High-titer, serum-free production of adeno-associated virus vectors by polyethyleneimine-mediated plasmid transfection in mammalian suspension cells.

Biotechnol Lett 29(11):1713-21 (2007) PMID 17636388

Adeno-associated virus (AAV)-based vectors belong to the most promising gene transfer vectors in clinical studies. To provide vector for late-stage clinical trials as well as for a potential commercial phase, a scalable, cGMP-compliant process is required. Nearly all vector production protocols currently approved in Phase I clinical trials rely on AAV production in adherent HEK 293 cells in the presence of serum. In this study, we present a helper- and serum-free production method of AAV vectors in suspension-adapted HEK 293 cells. The method is based on plasmid transfection with 25 kDa linear polyethyleneimine. Compared to existing methods, our system is highly scalable as cells grow in suspension, does not require animal-derived products or the use of an exogenous virus (adenovirus or baculovirus) and yields genomic titers equal to those obtained in adherent HEK 293 cells in the presence of serum. Most importantly, work load and cost could be dramatically reduced in comparison to earlier methods, when comparing the production of equivalent volumes of cell culture media. Thus, our protocol should appeal to both basic research laboratories and cGMP manufacturing units.

DOI: 10.1007/s10529-007-9441-3
Version: za2963e q8za5 q8zb7 q8zca q8zd0 q8ze1 q8zf1 q8zge

Similar articles you may find interesting…

  1. Magnetic particle-based time-resolved fluoroimmunoassay for the simultaneous determination of α-fetoprotein and the free β-subunit of human ...

    Analyst (2013) PMID 23671904

    These results demonstrate the feasibility and potential of the new method as a rapid and highly sensitive immunoassay that could be developed into a platform for multi-analyte determinations in clinical practice....
  2. Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS...

    Analyst (2013) PMID 23671909

    We found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accurac...
  3. Population III Stars and Remnants in High Redshift Galaxies

    arXiv:1305.1325 [astro-ph.CO] 6 May 2013

    We present a cosmological adaptive mesh Refinement simulation of an overdense region that forms a few 10^9 Msun dark Matter halos and over 13,000 Population III stars by redshift 15. We find that Most halos do not form Population III stars until they reach Mvir ~ 10^7 Msun Because this biased region...