Advanced search×

Analysis of the effective point of measurement of a thimble chamber dosimeter set parallel to the X-ray beam axis.

Igaku Butsuri 27(1):17-25 (2007) PMID 17917436

To measure the narrow beam used in stereotactic irradiation, installation of the ionization chamber parallel to the X-ray beam axis has been used instead of perpendicular installation. However, the definition of the effective point is a major problem in the parallel installation. In this study, we analyzed the effective point in parallel installation, and considered the prediction and evaluation of measurement point displacement. Relative dosimetry was carried out by installing the thimble ionization chamber in both perpendicular and parallel configurations. We then searched for the measurement point that coincided with the PDD of the perpendicular installation by using the displacement of the measurement point of the parallel installation. We found that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length and the cavity radius. Moreover, the effective point of measurement also depends on the beam quality and the field size. The amount of effective point displacement for the parallel installation was quantified with the linear expression of TPR(20,10). Our results showed that the amount of effective point displacement can be estimated by the ionization volume of the dosimeter and the energy used.

Version: za2963e q8za0 q8zbf q8zc4 q8zd0 q8zec q8zf1 q8zg5

Similar articles you may find interesting…

  1. Magnetic resonance imaging in chronic Achilles tendinopathy.

    Acta Radiol Suppl (2004) PMID 15586844

    We investigated different types of sequences, including gadolinium contrast medium-enhanced T1-WI images (CME T1-WI), and developed a precise method to measure tendon volume and mean intratendinous signal of the Achilles tendon. Study I aimed at evaluating 15 patients with chronic, painful Achilles...
  2. A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations.

    Phys Med Biol 50(21):5089-104 (2005) PMID 16237243

    A pencil beam algorithm as a component of an optimization algorithm for intensity modulated proton therapy (IMPT) is presented. The pencil beam algorithm is tuned to the special accuracy requirements of IMPT, where in heterogeneous geometries both the position and distortion of the Bragg peak and th...
  3. Editorial Board
    Author(s) unavailable

    Eur J Radiol 70(3):0 (2009)