Advanced search×

ALOX5AP variants are associated with in-stent restenosis after percutaneous coronary intervention

Atherosclerosis 201(1):7 (2008) PMID 18374923

Background: Use of drug-eluting stents (DES) has reduced in-stent restenosis after percutaneous coronary intervention (PCI); however, DES are associated with late stent thrombosis. There is no accurate way to predict in-stent restenosis, although risk factors for atherosclerosis overlap those for in-stent restenosis. Therefore, we evaluated atherosclerosis candidate genes for association with in-stent restenosis. Methods: We identified 46 consecutive cases that had undergone PCI with bare-metal stents who subsequently developed symptomatic in-stent restenosis of the target lesion (>=75% luminal narrowing) within 6 months. Forty-six age-, race-, vessel-diameter- and sex-matched controls without in-stent restenosis after PCI with bare-metal stent were also identified. Single-nucleotide polymorphisms (SNPs, N=82) from 39 candidate atherosclerosis genes were genotyped. Multivariable logistic regression models were used to test for association. Results: Five SNPs were associated with in-stent restenosis. Three ALOX5AP SNPs were most strongly associated, two with increased risk (OR 3.74, p=0.01; OR 3.46, p=0.02), and the third with decreased risk of in-stent restenosis (OR 0.09, p=0.004). Two ALOX5AP haplotypes were associated with in-stent restenosis (HapB: OR 3.13, p=0.03); and a haplotype similar to HapA: OR 0.14, p=0.0009). Conclusions: ALOX5AP, a gene within the inflammatory leukotriene pathway linked to and associated with coronary atherosclerosis, is also associated with in-stent restenosis. Genotyping these variants may help identify those at risk for in-stent restenosis who would benefit most from use of DES.

DOI: 10.1016/j.atherosclerosis.2008.01.011
Version: za2963e q8zaf q8zbe q8zc7 q8zdf q8ze3 q8zf3 q8zg3

Similar articles you may find interesting…

  1. Molecular self-assembly and applications of designer peptide amphiphiles.

    Chem Soc Rev 39(9):3480-98 (2010) PMID 20498896

    Short synthetic peptide amphiphiles have recently been explored as effective nanobiomaterials in applications ranging from controlled gene and drug release, skin care, nanofabrication, biomineralization, membrane protein stabilization to 3D cell culture and tissue engineering. This range of applicat...
  2. Reclassification of cardiovascular risk using integrated clinical and molecular biosignatures: Design of and rationale for the Measurement t...

    Am Heart J 160(3):0 (2010) PMID 20826242

    We describe the design of and rationale for the MURDOCK Cardiovascular Disease Study. Copyright © 2010 Mosby, Inc. All rights reserved....
  3. Thermoresponsive copolymer nanofilms for controlling cell adhesion, growth, and detachment.

    Langmuir 26(22):17304-14 (2010) PMID 20964301

    This study reports the development and use of a novel thermoresponsive polymeric nanofilm for controlling cell adhesion and growth at 37 °C, and then cell detachment for cell recovery by subsequent temperature drop to the ambient temperature, without enzymatic cleavage or mechanical...