A comparison of time-domain solutions for the full-wave equation and the parabolic wave equation for a diagnostic ultrasound transducer.

IEEE Trans Ultrason Ferroelectr Freq Control 55(3):730-3 (2008) PMID 18407863

A study of numerical solutions to the linear wave equation and the parabolic wave equation is presented. Finite-difference, time-domain methods are used to calculate the acoustic field emitted from a phased diagnostic ultrasound transducer in a non-attenuating medium. Results are compared to Field II, a simulation package that has been used extensively to linearly model transducers in ultrasound. The simulation of the parabolic equation can accurately predict the lateral beamplot for large f/#s, but, it exhibits 2-3 dB errors for small f/#s. It also overestimates the depth at which the focus occurs. For the considered array, it is shown that the finite-difference solution of the wave equation is accurate for a small and large f/#. The lateral beamplots and axial intensities are in excellent agreement with the Field II simulations.

Version: za2963e q8zac q8zba q8zcd q8zd9 q8zeb q8zfe q8zg9

Similar articles you may find interesting…

  1. Characterization of clutter in ultrasonic imaging using a nonlinear full-wave simulation method and in vivo human tissue.

    J Acoust Soc Am 127(3):1866 (2010) PMID 20330567

    We have performed simulations of clutter using a nonlinear, full-wave method to demonstrate the characteristics and sources of ultrasonic clutter. Representations of human abdominal layers, created from histological stains of human abdominal layers, were placed at the surface of the transducer. Poin...
  2. A heterogeneous nonlinear attenuating full-wave model of ultrasound.

    IEEE Trans Ultrason Ferroelectr Freq Control 56(3):474-88 (2009) PMID 19411208

    We present a numerical solution of the relaxation attenuation laws that allows modeling of arbitrary frequency dependent attenuation, such as that observed in tissue. A perfectly matched layer (PML) is implemented at the boundaries with a numerical implementation that allows the PML to be used with...
  3. Rapid tracking of small displacements with ultrasound.

    IEEE Trans Ultrason Ferroelectr Freq Con... 53(6):1103-17 (2006) PMID 16846143

    These results are used to implement a real-time ARFI imaging system using a commercial ultrasound scanner and a computer cluster. Images processed with the algorithms are examined in an ex vivo liver ablation study....