Mechanical circulatory support (MCS) devices are a guideline-recommended treatment option for a small subset of advanced heart failure patients. MCS has the potential to become more prominent in the management of Acute Heart Failure Syndromes (AHFS) as device technology advances and as clinical trials consistently discover neutral or harmful effects with pharmacologic therapies hypothesized to be beneficial in this population. While it is now possible to identify AHFS patients who are at high risk of death, the therapeutic options available to improve their long-term outcomes are limited. MCS therapy in this population offers a "bridge to recovery" strategy; these patients may have viable myocardium that responds favorably to the influence of MCS on neurohormones, cytokines, and/or reverse remodeling. Patients at high risk for mortality who have a substantial likelihood of benefiting from MCS can be easily identified using standard clinical criteria developed from large observational databases. MCS technology is rapidly evolving, and risks related to implantation are declining. It is evident that rigorous clinical trial testing of the potential risks, benefits, and economic implications of MCS in patients with AHFS will need to be conducted before the "routine" application of this aggressive therapy. This paper examines the rationale for conducting trials of MCS devices in patients with AHFS, and it explores considerations for patient selection and appropriate endpoints. This manuscript was generated from discussions on this issue during the third international meeting of the International Working Group on AHFS held in Washington, DC, April 8-9, 2006.

DOI: 10.1007/s10741-008-9097-7
Version: za2963e q8za9 q8zbc q8zc2 q8zdc q8ze4 q8zf1 q8zgc

Similar articles you may find interesting…

  1. From powder to technical body: the undervalued science of catalyst scale up.

    Chem Soc Rev (2013) PMID 23648466

    We point out the multiple functions that additives could provide by enhancing the mass and heat transfer properties, acting as co-catalysts, or imparting improved chemical, mechanical, or thermal stability. Recent exemplary studies developing rational approaches to prepare, characterise, and evaluat...
  2. Thermospermine levels are controlled by an auxin-dependent feedback-loop mechanism in Populus xylem.

    Plant J (2013) PMID 23647338

    We present data in the Populus model system supporting presence of a negative feedback control of thermospermine levels in stem xylem tissues, the main site of thermospermine biosynthesis. While overexpression of the ACL5 homolog in Populus, POPACAULIS5, resulted in strong upregulation of ACL5 expre...
  3. Inhaled Carbon Monoxide Accelerates Resolution of Inflammation via Unique Proresolving Mediator-Heme Oxygenase-1 Circuits.

    J Immunol (2013) PMID 23650615

    We employed a systems approach to determine the impact of CO in resolution active programs during self-limited inflammation in mice. Compared with ambient air, inhaled CO gas (250 ppm) significantly limited PMN infiltration (∼44%, 6 h) into peritoneum and shortened resolution interval from 4 to 2...