Advanced search×

In Vivo Wear Rate of the Birmingham Hip Resurfacing Arthroplasty

J Arthroplasty 24(6):6 (2009) PMID 18757168

The wear of 8 femoral and 2 acetabular components of the Birmingham Hip Resurfacing (Midland Medical Technologies Ltd, Birmingham, UK) was measured using a coordinate measuring machine (CMM5; SIP, Geneva, Switzerland). After a median in situ time of 13 months, measurements of the Birmingham Hip Resurfacing femoral heads revealed a median volumetric wear of 2.9 mm^3. In one case with a cup abduction angle of 70^o, a significantly higher wear of 17.8 mm^3 was found. The 2 acetabular components showed volumetric wear of 5.4 and 27.6 mm^3 after 14 and 15 months in vivo. The wear rates of the investigated femoral components were somewhat, but not significantly, higher than the previously investigated 28-mm Metasul heads (median, 0.8 mm^3; Zimmer GmbH, Winterthur, Switzerland).

Copyright © 2009 Elsevier Ltd. All rights reserved.

DOI: 10.1016/j.arth.2008.06.022
Version: za2963e q8za2 q8zbb q8zcd q8zd5 q8ze8 q8zfb q8zg0

Similar articles you may find interesting…

  1. Simplified negative pressure wound therapy: clinical evaluation of an ultraportable, no-canister system.

    Int Wound J (2013) PMID 23647737

    The aim of this study was to evaluate a prototype negative pressure wound therapy (NPWT) system that has been developed to simplify NPWT for wounds at the lower end of the acuity scale. The new device has a single preset pressure of -80 mmHg, is single use and operates without an e...
  2. Differential Coordination Demands in Fe versus Mn Water-Soluble Cationic Metalloporphyrins Translate into Remarkably Different Aqueous Redox...

    Inorg Chem (2013) PMID 23646875

    Our data suggest that in vivo, redox-driven degradation of Fe porphyrins resulting in Fe release plays a major role in their biological action. Possibly, iron reconstitutes enzymes bearing [4Fe-4S] clusters as active sites. Under the same experimental conditions, (OH)(H2O)FePs do not cause mouse art...
  3. Formulation and In Vivo Evaluation of Orally Disintegrating Tablets of Clozapine/Hydroxypropyl-β-cyclodextrin Inclusion Complexes.

    AAPS PharmSciTech (2013) PMID 23649995

    The aim of this study was to improve the solubility and oral bioavailability of clozapine (CLZ), a poorly water-soluble drug subjected to substantial first-pass metabolism, employing cyclodextrin complexation technique. The inclusion complexes were prepared by an evaporation method....