Advanced search×

Characterization of nebulized liposomal amikacin (Arikace) as a function of droplet size.

J Aerosol Med Pulm Drug Deliv 21(3):245-54 (2008) PMID 18759656

The stress of nebulization has been shown to alter the properties of liposomal drugs. What has not been demonstrated is whether nebulized liposomes differ as a function of droplet size. Because droplet size influences lung deposition, liposomes with different properties could be deposited in different areas of the lung (e.g., central vs. peripheral). In this report, a liposomal amikacin formulation (Arikace, a registered trademark of Transave, Inc., Monmouth Junction, NJ) that is being developed as an inhaled treatment for gram negative infections was aerosolized with an eFlow (registered trademark of PARI, GmbH, Munich, Germany) nebulizer, reclaimed from the various stages of an Andersen cascade impactor (ACI) and analyzed for lipid-to-drug (L/D) (w/w) ratio, amikacin retention, and liposome size. For the nebulized solution, 99.7% of the total deposited drug was found on ACI stages 0 through 5, which have cutoff diameters of 9, 5.8, 4.7, 3.3, 2.1, and 1.1 microm, respectively. Properties were found to differ for drug reclaimed on stage 0 compared stages 1-5, which were not different from one another. For drug found on stages 1-5 (97% of total drug), the averages (n = 3) for L/D, percent encapsulated amikacin, and liposome mean diameter ranged from 0.59 to 0.68 (w/w), 71% to 75%, 248 to 282 nm, respectively. Drug found on stage 0 (2.8% of total drug) had an average L/D ratio of 0.51 and average liposome mean diameter of 375 nm. Examination of another batch of liposomal amikacin revealed no statistically significant differences between drug reclaimed on stages 0-5. Although a droplet size dependence was noted for one batch of Arikace aerosolized with the eFlow, the effect was considered to be inconsequential because the fraction in doubt represented nonrespirable particles >9 microm and accounted for <3% of the total deposited dose. The methodology applied here appears useful in evaluating aerosolized liposome systems. However, our results should not be assumed to apply to other liposome/drug compositions and nebulizers.

DOI: 10.1089/jamp.2008.0686
Version: za2963e q8zaf q8zb6 q8zc2 q8zd6 q8zed q8zf3 q8zg8

Similar articles you may find interesting…

  1. Characterization of Zwitterionic Phosphatidylcholine-Based Bilayer Vesicles as Efficient Self-Assembled Virus-Like Gene Carriers.

    Mol Biotechnol (2013) PMID 23649598

    We were able to encapsulate pDNA without using multivalent cations and with high efficiency (98 %) into noncationic lipid bilayer vesicles. These liposomes which were composed of dimyristoyl-sn-glycero-3-phosphocholine unlike cationic liposomes, were nontoxic. The obtained liposome structure was ab...
  2. Synthesis and ionophoric activities of functionalized bis(choloyl) conjugates with a rigid core.

    Bioorg Med Chem Lett (2013) PMID 23639545

    Three bis(choloyl) conjugates bearing a rigid p-phenylenediamine/p-bis(aminomethyl)benzene linker and amino/acetamido groups were synthesized, and fully characterized on the basis of (1)H NMR, ESI-MS and HRMS. Their ionophoric activities were investigated by means of pH discharge ass...
  3. Novel chitosan derivative for temperature and ultrasound dual-sensitive liposomal microbubble gel.

    Carbohydr Polym 94(1):17-23 (2013) PMID 23544504

    In this study, a novel liposome-loaded microbubble gel based on N-cholesteryl hemisuccinate-O-sulfate chitosan (NCHOSC) was designed. The structure of the NCHOSC was characterized by FTIR and (1)H NMR. The liposomal microbubble gel based on NCHOSC with a high encapsulation efficiency...