Magnetic field effects on the energy deposition spectra of MV photon radiation.

Phys Med Biol 54(2):243-57 (2009) PMID 19088391

Several groups worldwide have proposed various concepts for improving megavoltage (MV) radiotherapy that involve irradiating patients in the presence of a magnetic field-either for image guidance in the case of hybrid radiotherapy-MRI machines or for purposes of introducing tighter control over dose distributions. The presence of a magnetic field alters the trajectory of charged particles between interactions with the medium and thus has the potential to alter energy deposition patterns within a sub-cellular target volume. In this work, we use the MC radiation transport code PENELOPE with appropriate algorithms invoked to incorporate magnetic field deflections to investigate electron energy fluence in the presence of a uniform magnetic field and the energy deposition spectra within a 10 microm water sphere as a function of magnetic field strength. The simulations suggest only very minor changes to the electron fluence even for extremely strong magnetic fields. Further, calculations of the dose-averaged lineal energy indicate that a magnetic field strength of at least 70 T is required before beam quality will change by more than 2%.

DOI: 10.1088/0031-9155/54/2/005
Version: za2963e q8zaf q8zb3 q8zc3 q8zdb q8zef q8zf6 q8zg6

Similar articles you may find interesting…

  1. Intervertebral disc internal deformation measured by displacements under applied loading with MRI at 3T.

    Magn Reson Med (2013) PMID 23650022

    The displacement and strain precisions were 24 µm and 0.3% strain, respectively, under the imaging parameters used in this study. Displacements and strains were measured within the intervertebral disc, but no correlations were found with the T2 values. CONCLUSION: The translation of dualMRI to a 3T...
  2. Phonon coupling effects in magnetic moments of magic and semi-magic nuclei

    arXiv:1305.1123 [nucl-th] 6 May 2013

    We calculated the gyromagnetic ratio G_L^{ph} of all low-lying phonons in 208Pb. For the 3^-_1 state it is rather Close to the Bohr-Mottelson model prediction whereas for other L-phonons, two 5^- and six positive parity states, the difference from the Bohr-Mottelson Values is significant....
  3. Cyclotron parametric resonance in microwave-irradiated two-dimensional electron system

    arXiv:1305.1238 [cond-mat.mes-hall] 6 May 2013

    We suggest an explanation of this phenomenon in Terms of the cyclotron parametric resonance in 2DES. We develop the Hydrodynamic theory of 2D electron liquid in inhomogeneous microwave (MW) Electric field. We demonstrate that excitation of virtual Bernstein Magnetoplasma modes at the MW frequency ne...