Advanced search×

Non-invasive methods and techniques for central blood pressure estimation: procedures, validation, reproducibility and limitations.

Audio, Transactions of the IRE Profession... 15(3):245-53 (2009) PMID 19149616

Hypertension is a major risk factor for a wide range of cardiovascular diseases and is typically identified by measuring blood pressure (BP) at the brachial artery. Although such a measurement may accurately determine diastolic BP, it does not accurately reflect systolic BP. This is mainly attributed to the fact that blood pressure waveform is distorted as it travels outward from the heart due to the presence of wave reflections from the peripheral arteries. Due to this distortion, blood pressure measured at the brachial artery provides an inaccurate measure of central aortic systolic pressure. However, central systolic BP is an important factor determining cardiac function and work, while central diastolic BP may determine coronary flow. Consequently central (aortic and carotid) pressures are pathophysiologically more relevant than peripheral pressures and thus their non-invasive accurate estimation is challenging and clinically necessary. The purpose of this review is to present methods and techniques that are used for the estimation of central blood pressures and to describe and discuss issues regarding methodological procedures, reproducibility, validity and limitations.

Version: za2963e q8zac q8zbb q8zcd q8zd3 q8ze3 q8zf5 q8zg9

Similar articles you may find interesting…

  1. Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence.

    Med Biol Eng Comput 49(4):409-15 (2011) PMID 21404079

    We provide first experimental evidence that electrical impedance tomography (EIT) is capable of measuring pressure pulses directly within the descending aorta. To obtain a wide range of BP values, we administrated noradrenalin and nitroglycerine to an anesthetized pig under mechanical ventilation. A...
  2. Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger.

    Exp Physiol 90(4):437-46 (2005) PMID 15802289

    We review recent developments in the methodology of non-invasive finger arterial pressure measurement and the information about arterial flow that can be obtained from it. Continuous measurement of finger pressure based on the volume-clamp method was introduced in the early 1980s both for research p...
  3. The reduction of infarct size--forty years of research.

    Rev Port Cardiol 29(6):1037-53 (2010) PMID 20964114

    I for small infarcts to Class IV with major necrosis, (involving more than 30% of the LV free wall area, the majority of these being fatal). Along with these advances, a series of experimental studies have shown that myocardial ischemia depends on the oxygen supply-demand imbalance, highlighting the...