Advanced search×

Chest CT Performed with 3D and z-Axis Automatic Tube Current Modulation Technique

Acad Radiol 16(4):6 (2009) PMID 19268857

Rationale and Objectives: Chest computed tomographic (CT) scans are the most effective examinations for detecting lung cancer at an early stage. In chest CT examinations, it is important to consider the reduction of radiation dose, particularly to the mammary gland. The objective of this study was to assess breast doses and effective doses on chest CT examinations between three-dimensional and z-axis automatic tube current modulation (ATCM) techniques. Materials and Methods: Absorbed dose to the breast, lung, mediastinum, and skin was evaluated with an anthropomorphic phantom and radiophotoluminescence glass dosimeters using two different CT scanners. The dosimeters were placed inside and outside the phantom. The phantom was scanned using three-dimensional and z-axis ATCM techniques after scanning localizer radiographs from the horizontal and vertical directions. After scanning, each organ dose was calculated. Moreover, the dose-length product recorded in the dose reports was examined, and each effective dose was calculated. Results: Compared with z-axis ATCM, three-dimensional ATCM reduced breast dose by 0.7% to 18.6% and effective dose by 4.9% to 10.2%. In particular, three-dimensional ATCM reduced frontal breast dose. For other organs, three-dimensional ATCM reduced absorbed doses by 3.4% to 13.6% compared to z-axis ATCM. Conclusion: Three-dimensional ATCM can reduce absorbed doses to the breast and other organs, in addition to reducing effective dose, compared to z-axis ATCM.

Copyright © 2009 Elsevier Ltd. All rights reserved.

DOI: 10.1016/j.acra.2008.11.005
Version: za2963e q8zaf q8zbc q8zcf q8zdb q8ze8 q8zf8 q8zg0

Similar articles you may find interesting…

  1. Magnetic resonance imaging in chronic Achilles tendinopathy.

    Acta Radiol Suppl (2004) PMID 15586844

    We investigated different types of sequences, including gadolinium contrast medium-enhanced T1-WI images (CME T1-WI), and developed a precise method to measure tendon volume and mean intratendinous signal of the Achilles tendon. Study I aimed at evaluating 15 patients with chronic, painful Achilles...
  2. Editorial Board
    Author(s) unavailable

    Eur J Radiol 70(3):0 (2009)

  3. A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma

    Eur J Radiol 79(2):5 (2011) PMID 20193995

    Assuming that the OM line and bed were vertical, intraocular doses varied between 52 and 140%, 17-138%, and 90-142% during helical, non-helical, and helical CT angiographic examinations, respectively. Intraocular doses increased when the phantom was tilted cranially. CONCLUSION: If possible, the bes...