Advanced search×

Continuous monitoring of intraocular pressure: rationale and progress toward a clinical device.

J Glaucoma 18(4):272-9 (2009) PMID 19365190

Intraocular pressure (IOP) is a dynamic physiologic parameter with regular circadian variations and unpredictable short-term and long-term fluctuations. Current methods of measuring IOP are suboptimal with a typical clinical practice only performing periodic IOP measurements during regular office hours. Diurnal and 24-hour IOP measurements obtained on an in-patient basis can increase measurements but are inconvenient and expensive, and do not allow ambulatory monitoring of IOP. The goal of continuous IOP monitoring is to provide automated 24-hour recording of ambulatory IOP. Continuous IOP monitoring involves 2 complementary paradigms. Temporary noninvasive monitoring, possibly involving a contact lens-based pressure sensor, would be used to measure 24-hour IOP on a periodic basis. Permanent monitoring would be more invasive, using an implantable pressure sensor. Despite numerous previous attempts at continuous IOP monitoring, a device suitable for clinical use is not yet available. However, devices currently in development for permanent IOP monitoring seem to be nearly ready for human testing. The technologic issues for temporary monitoring may be greater than for permanent monitoring.

DOI: 10.1097/IJG.0b013e3181862490
Version: za2963e q8za2 q8zb6 q8zc0 q8zd1 q8ze0 q8zfa q8zg2

Similar articles you may find interesting…

  1. Change in area of geographic atrophy in the Age-Related Eye Disease Study: AREDS report number 26.

    Arch Ophthalmol 127(9):1168-74 (2009) PMID 19752426

    Objective To characterize progression of geographic atrophy (GA) associated with age-related macular degeneration in AREDS as measured by digitized fundus photographs. Methods Fundus photographs from 181 of 4757 AREDS participants with a GA area of at least 0.5 disc areas at baseline or from parti...
  2. Evaluation of the Age-Related Eye Disease Study Clinical Lens Grading System

    Ophthalmology 117(11):0 (2010) PMID 20561686 PMCID PMC2944007

    Interrater agreements were in the moderate to substantial range for the clinical assessment of lens opacities. Inherent differences in cataract classification systems that rely on slit lamp vs photographic assessments of lens opacities may explain some of the disagreement noted between slit lamp and...
  3. Nrf2-mediated liver protection by sauchinone, an antioxidant lignan, from acetaminophen toxicity through the PKCδ-GSK3β pathway.

    Br J Pharmacol 163(8):1653-65 (2011) PMID 21039417 PMCID PMC3166693

    Our results demonstrate that sauchinone protects the liver from APAP-induced toxicity by activating Nrf2, and this effect is mediated by PKCδ activation, which induces inhibitory phosphorylation of GSK3β. © 2010 The Authors. British Journal of Pharmacology © 2010 The British Phar...