Advanced search×

Comparison of pseudophakic visual quality in spherical and aspherical intraocular lenses

Can J Ophthalmol 44(3):5 (2009) PMID 19491981

Objective: This study compares the visual performance of spherical and aspherical intraocular lenses (lOLs) by measuring higher-order aberration and contrast sensitivity (CS) values. Design: Prospective controlled study. Participants: Fifty-seven patients with age-related cataract (61 eyes). Methods: Patients were randomly allocated to 1 of 3 groups and implanted with either aspherical IOLs, Acrysof IQ (SN60WF) or Tecnis Z9001, or a spherical IOL, Acrysof Natural. Patients underwent routine examinations, including visual acuity, slit-lamp checks, and best-corrected visual acuity (BCVA), as well as measurement of higher-order aberrations and CS values, preoperatively and at 1 week, 1 month, and 2 months postoperatively. Results: All the patients had a BCVA better than 20/30 postoperatively. The spherical aberrations of the IQ group and Tecnis group were both lower than in the Natural (control) group (IQ: p < 0.05); there was no significant difference in coma and higher-order aberration. No statistically significant difference was found in spherical aberration, coma, or higher-order aberration between the IQ and Tecnis groups. Under glare conditions, the CS values of the 2 aspherical IOLs were obviously better (IQ: p < 0.05; Tecnis: p < 0.05) than the CS value of the spherical IOL group at low frequency (IQ: 6.3^o, Tecnis: 4.0^o); under non-glare conditions there was a significant difference in CS values between the aspherical IOL groups and the control group (IQ: p < 0.01) at low frequency (both 6.3^o). There was no statistical difference between the IQ and the Tecnis groups with or without glare. Conclusions: An aspherical IOL can effectively reduce spherical aberration after cataract surgery, enhance CS values, and improve visual quality compared with traditional spherical IOLs for age-related cataract. However, there was no statistically significant difference in postoperative aberration and CS values between the Acrysof IQ and Tecnis Z9001 aspherical IOLs.

DOI: 10.3129/i08-121
Version: za2963e q8za3 q8zbf q8zc7 q8zdb q8zeb q8zf3 q8zg7

Similar articles you may find interesting…

  1. Comparison of antibiotic-only and antibiotic-steroid combination treatment in corneal ulcer patients: double-blinded randomized clinical tri...

    Can J Ophthalmol 46(1):40-5 (2011) PMID 21283156

    No benefit was demonstrated in our primary outcome for using steroids in combination with antibiotic therapy in treatment of corneal ulcers. This study suggests that the early addition of steroids to the antibiotic treatment of corneal ulcers does not seem to be harmful when employed in a closely mo...
  2. Fluorescent chemosensor for detection and quantitation of carbon dioxide gas.

    Audio, Transactions of the IRE Profess... 132(40):13951-3 (2010) PMID 20853831

    We report a CO(2) assay scheme over a wide concentration range, utilizing a fluorogen with an aggregation-induced emission feature and a liquid with tunable polarity and viscosity. The CO(2) sensing process is specific, quantitative, and interferent tolerant....
  3. Synthesis and Helical Conformation of Novel Optically Active Liquid Crystalline Poly( p -phenylen...

    Macromolecules 42(14):5053-5061 (2009)