Advanced search×

High-frequency mode conversion technique for stiff lesion detection with magnetic resonance elastography (MRE)

Magn Reson Med 62(6):1457-1465 (2009) PMID 19859936 PMCID PMC3027306

A novel imaging technique is described in which the mode conversion of longitudinal waves is used for the qualitative detection of stiff lesions within soft tissue using magnetic resonance elastography (MRE) methods. Due to the viscoelastic nature of tissue, high-frequency shear waves attenuate rapidly in soft tissues but much less in stiff tissues. By introducing minimally-attenuating longitudinal waves at a significantly high frequency into tissue, shear waves produced at interfaces by mode conversion will be detectable in stiff regions, but will be significantly attenuated and thus not detectable in the surrounding soft tissue. This contrast can be used to detect the presence of stiff tissue. The proposed technique is shown to readily depict hard regions (mimicking tumors) present in tissue-simulating phantoms and ex vivo breast tissue. In vivo feasibility is demonstrated on a patient with liver metastases in whom the tumors are readily distinguished. Preliminary evidence also suggests that quantitative stiffness measurements of stiff regions obtained with this technique are more accurate than those from conventional MRE because of the short shear wavelengths. This rapid, qualitative technique may lend itself to applications in which the localization of stiff, suspicious neoplasms is coupled with more sensitive techniques for thorough characterization. Magn Reson Med, 2009. (c) 2009 Wiley-Liss, Inc.

DOI: 10.1002/mrm.22091
Version: za2963e q8za6 q8zb1 q8zcf q8zd4 q8ze1 q8zf0 q8zgf

Similar articles you may find interesting…

  1. Cognitive effects of deep brain stimulation for essential tremor: evaluation at 1 and 6 years.

    J Neural Transm (2013) PMID 23649123

    We examined nine ET patients before surgery (PRE-SURGERY), and 1 and 6 years thereafter with DBS switched on (DBS-ON) and off (DBS-OFF). Standardized neuropsychological tests and reaction time tests were applied. There were no differences in tasks of verbal fluency, memory, and executive and intell...
  2. Human Genetic Variation Influences Vitamin C Homeostasis by Altering Vitamin C Transport and Antioxidant Enzyme Function.

    Nutrition (2013) PMID 23642198

    We examine the extent of the variation in these genes, their impact on vitamin C status, and their potential role in altering chronic disease risk. We conclude that future epidemiological studies should take into account genetic variation in order to successfully determine the role of vitamin C nutr...
  3. Multidrug Resistance-Associated Protein 2 (MRP2/ABCC2) Haplotypes Significantly Affect the Pharmacokinetics of Tacrolimus in Kidney Transpla...

    Clin Pharmacokinet (2013) PMID 23633119

    This is the first report showing that MRP2/ABCC2 has a crucial impact on the pharmacokinetics of tacrolimus in a haplotype-specific manner. Determination of the ABCC2 as well as CYP3A5 genotype may be useful for more accurate tacrolimus dosage adjustment....