Advanced search×

Influence of different power outputs of erbium, chromium:yttrium-scandium-gallium-garnet laser and acid etching on shear bond strengths of a dual-cure resin cement to enamel.

Lasers Med Sci 26(1):13-9 (2011) PMID 20016923

The purpose of the study was to determine if the irradiation of enamel with laser of different output powers might be viable alternatives to acid etching for the bonding of resin luting agents. Seventy-seven maxillary central incisors, extracted for periodontal reasons, were used. The enamel was etched with an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser operated at one of six power outputs (0.5 W, 0.75 W, 1 W, 1.5 W, 1.75 W and 2 W) or with 38% phosphoric acid. Seventy teeth were used for the bond strength experiments, and the remaining seven (one specimen for each group) were used for scanning electron microscopy (SEM) to determine the topography and morphology of the treated enamel surface. The acid-etched group yielded the highest mean of shear bond strength (13.5 ± 2.8 MPa). The means of the shear bond strength for the teeth irradiated at 0.5 W, 0.75 W, 1 W, 1.5 W , 1.75 W and 2 W laser were 3.28 ± 2.4 MPa, 5.44 ± 3.4 MPa, 8.8 ± 4.5 MPa, 10.2 ± 4.0 MPa, 11.4 ± 4.8 MPa and 11.9 ± 4.3 MPa, respectively. Laser irradiation at 1.5 W, 1.75 W and 2 W produced a type III acid-etched pattern similar to that produced by acid etching. No significant enamel surface etching was obtained by 0.5 W or 0.75 W laser irradiation. Irradiation at 0.5 W and 0.75 W produced a type V acid-etched pattern. We concluded that the mean shear bond strength and enamel surface etching obtained with Er,Cr:YSGG laser (operated at 1.5 W and 1.75 W for 15 s) is comparable to that obtained with acid etching.

DOI: 10.1007/s10103-009-0742-8
Version: za2963e q8zab q8zb6 q8zc2 q8zde q8zee q8zf7 q8zg7

Similar articles you may find interesting…

  1. Effect of Er,Cr:YSGG laser parameters on shear bond strength and microstructure of dentine.

    Photomed Laser Surg 27(3):481-6 (2009) PMID 19405817

  2. Tensile bond strength of dentin adhesives on acid- and laser-etched dentin surfaces.

    Quintessence Int (Berl) 40(10):865-74 (2009) PMID 19898719

    To evaluate tensile bond strengths of 2 dentin bonding agents containing solvents on Nd:YAG and Er,Cr:YSGG laser-etched dentin surface. Occlusal enamel of 146 molars was removed, and exposed surfaces were ground with a diamond bur to produce bur-cut dentin surfaces. Of those teeth, 120 were assigned...
  3. Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions.

    Lasers Med Sci 24(1):67-73 (2009) PMID 18027064

    The aim of this study was to investigate whether distinct cooling of low fluence erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation would influence adhesion. Main factors tested were: substrates (two), irradiation conditions (three), and adhesives (three). A 750 μm diame...