The skull unfolded: a cranial CT visualization algorithm for fast and easy detection of skull fractures.

Radiology 255(2):553-62 (2010) PMID 20332373

PURPOSE: To retrospectively assess the rate of detection of skull fractures at cranial computed tomography (CT) achieved with the use of curved maximum intensity projections (MIPs) compared with that achieved by reading transverse sections only. MATERIALS AND METHODS: The institutional review board approved this research and waived informed consent. A curved thin (3-mm) MIP of the skull cap and a curved thick (50-mm) MIP of the skull base were obtained from the cranial CT data in 200 consecutive patients with head trauma. Four radiologists (two residents without experience in cranial CT and two consultants) independently evaluated all cases. Each radiologist reported findings in 100 patients by using transverse sections only and findings in the other 100 patients by using the unfolded view. The radiologists were blinded to patient names, and patient and group orders were randomized. The results were compared with a standard of reference established by two experts from all prior reading results, all reconstructions, and high-spatial-resolution multiplanar reformats. Logistic regression with repeated measurements was used for statistical analysis. RESULTS: The experts found 63 fractures in 30 patients. When transverse sections only were used, the mean patient-based fracture detection rate was 43% (13 of 30) for inexperienced and 70% (21 of 30) for experienced readers; with curved MIPs, the rates were 80% (24 of 30) and 87% (26 of 30), respectively. Overall sensitivity was higher with curved MIPs (P < .001); specificity was higher with transverse sections (P < .001). CONCLUSION: Curved MIPs enable a significantly higher fracture detection rate than transverse sections. They also considerably close the experience gap in fracture detection rate between residents and experts.

DOI: 10.1148/radiol.10091096
Version: za2963e q8zac q8zbf q8zc0 q8zdd q8zed q8zf8 q8zg4

Similar articles you may find interesting…

  1. Spatial population structure of the Neotropical tiger catfish Pseudoplatystoma metaense: skull and otolith shape variation.

    J Fish Biol 82(5):1453-68 (2013) PMID 23639147

    Using geometric morphometrics, the skull and otolith of tiger catfish Pseudoplatystoma metaense were analysed to identify population structure in tributaries of the Apure River (i.e. the Sarare, Caparo, Guanare, Portuguesa and San Carlos Rivers) in the Orinoco basin, Venezuela. The a...
  2. Evaluation of Automated 2D-3D Image Overlay System Utilizing Subtraction of Bone Marrow Image for EVAR: Feasibility Study.

    Eur J Vasc Endovasc Surg (2013) PMID 23642524

    Arteriography was performed only twice to confirm the precision of the position of renal artery and the final evaluation. Twenty patients underwent EVAR with Medtronic Endurant, Gore Excluder, or COOK Zenith using "3D Roadmap". The origin of the renal artery and iliac bifurcation were registered wit...
  3. The continuum of detection and awareness of visual stimuli within the blindfield: from blindsight to the sighted-sight.

    Invest Ophthalmol Vis Sci (2013) PMID 23633654

    At retinal locations deep within the field defect, repeated stimulation can lead to blindsight performance (type I, detection without awareness), followed by detection with reported awareness (type II blindsight) and eventual reported visual experiences. The findings indicate that conscious awarenes...