BIOMED APPL 878(15-16):10 (2010) PMID 20382576

A reagent, 1-(4-isopropyl) phenyl-3-methyl-5-pyrazolone (PPMP) has been synthesized and used for high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) determination of pre-column labeled carbohydrates. Monosaccharides have been quantitatively converted into mono-PPMP-labeled derivatives with 28% aqueous ammonia as a catalyst at 80^oC during 70min. Mono-PPMP derivatives have been demonstrated to exhibit better chemical stability than bis-PMP ones. PPMP-labeled mixture of twelve monosaccharides (galactosamine, glucosamine, galacturonic acid, glucuronic acid, galactose, glucose/N-acetylgalactosamine, N-acetylglucosamine, xylose, arabinose, mannose, fucose, and rhamnose) has been well separated by a reverse-phase HPLC and detected by on-line ESI-MS method under optimized conditions. The data on characteristic fragment ions of the 13 PPMP-labeled monosaccharides with MS^2 data have been collected. The suggested method exhibits good linearity (correlation coefficients>0.9975) between the peak areas and the concentration of monosaccharides in a broad concentration range and good reproducibility (RSD<3.19%). The developed method has been successfully applied to analyze the monosaccharide composition of natural Spirulina polysaccharide SPPB-1.

Copyright © 2010 Elsevier Ltd. All rights reserved.

DOI: 10.1016/j.jchromb.2010.03.027
Version: za2963e q8za6 q8zbd q8zc0 q8zda q8zee q8zfb q8zgf

Similar articles you may find interesting…

  1. Microwave-assisted one-pot synthesis of pyrazolone derivatives under solvent-free conditions.

    Molecules 15(5):3593-601 (2010) PMID 20657501

    An efficient one-pot method to generate structurally diverse and medicinally interesting pyrazolone derivatives in good to excellent yields of 51-98% under microwave irradiation and solvent-free conditions has been developed.
  2. Vitamin K in milk and infant formulas: determination and distribution of phylloquinone and menaquinone-4.

    Analyst 122(5):465-9 (1997) PMID 9246814

    A method is described for the determination of phylloquinone and menaquinones following enzymatic digestion, extraction and a single-stage HPLC technique utilizing post-column reduction with zinc and fluorescence detection. The technique is applicable to both routine compliance control of phylloquin...