Advanced search×

Evaluation of Positioning Accuracy of Four Different Immobilizations Using Cone-Beam CT in Radiotherapy of Non-Small-Cell Lung Cancer

Int J Radiat Oncol Biol Phys 77(4):8 (2010) PMID 20400243

Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four immobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SBF), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients.

DOI: 10.1016/j.ijrobp.2009.09.049
Version: za2963e q8za7 q8zb9 q8zc7 q8zd8 q8ze3 q8zfe q8zg2

Similar articles you may find interesting…

  1. Diagnostic accuracy of premanipulative vertebrobasilar insufficiency tests: A systematic review

    Man Ther 18(3):177-182 (2013) PMID 23127991

    Of the 1677 potential citations only 4 studies were included, all of questionable quality. Sensitivity was low and ranged from 0 to 57%, specificity from 67 to 100%, positive predictive value from 0% to 100%, and negative predictive value from 26 to 96%. The positive likelihood ratio ranged from 0.2...
  2. Diagnostic accuracy of preoperative alpha-fetoprotein as an ovarian tumor marker in children and adolescents: not as good as we thought?

    Pediatr Surg Int (2013) PMID 23653236

    Twenty patients (18.2 %) had non-benign ovarian neoplasms, of which 12 had GCT/IT (10.9 %). In diagnosing GCT/IT versus non-GCT/IT, specificity of preoperative serum AFP was 87.8 %, sensitivity 66.7 %, and AUC 0.853. Excluding infants to remove the effects of increased variance in AFP in this gr...
  3. Matrix metalloproteinase, vitamin A and methylprednisolone effects on experimentally induced amyloid arthropathy.

    Biotech Histochem (2013) PMID 23647009

    We evaluated the role of some matrix metalloproteinases (MMPs) in enhancing the effect of vitamin A and the inhibiting effect of methylprednisolone on amyloid arthropathy in brown layer chicks. We used 100 one-day-old Isa brown layer chicks. The chicks were allocated to one of four groups as follows...