Ceramic capillary electrophoresis chip for the measurement of inorganic ions in water samples.

Analyst 135(5):965-70 (2010) PMID 20419244

We present a microchip capillary electrophoresis (CE) device build-up in low temperature co-fired ceramics (LTCC) multilayer technology for the analysis of major inorganic ions in water samples in less than 80 s. Contactless conductivity measurement is employed as a robust alternative to direct-contact conductivity detection schemes. The measurement electrodes are placed in a planar way at the top side of the CE chip and are realized by screen printing. Laser-cutting of channel and double-T injector structures is used to minimize irregularities and wall defects, elevating plate numbers per meter up to values of 110,000. Lowest limit of detection is 6 microM. The cost efficient LTCC module is attractive particularly for portable instruments in environmental applications because of its chemical inertness, hermeticity and easy three-dimensional integration capabilities of fluidic, electrical and mechanical components.

DOI: 10.1039/b922501c
Version: za2963e q8za8 q8zb8 q8zc2 q8zd9 q8ze1 q8zf6 q8zgd

Similar articles you may find interesting…

  1. Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment.

    Integr Biol (Camb) (2013) PMID 23644926

    We describe a microfluidic device lined by living human kidney epithelial cells exposed to fluidic flow that mimics key functions of the human kidney proximal tubule. Primary kidney epithelial cells isolated from human proximal tubule are cultured on the upper surface of an extracellular matrix-coat...
  2. Manipulating ionic strength to improve single cell electrophoretic separations.

    Talanta (2013) PMID 23622546

    A capillary electrophoresis system with ultrasensitive two-color laser-induced fluorescence detection was used to probe the effect of ionic strength on single cell separations of glycosphingolipids. Differentiated PC12 cells were incubated with two ganglioside substrates tagged with...
  3. Real-time detection of the chemokine CXCL12 in urine samples by surface plasmon resonance.

    Talanta (2013) PMID 23618162

    We tested for CXCL12 in urine samples from rheumatoid arthritis patients, who have elevated levels of this chemokine in plasma and synovial fluid. The biosensor method allowed sensitive, reproducible CXCL12 detection in the physiological range, suggesting its value for the diagnosis of autoimmune di...