Advanced search×

The size of the proton.

Nature 466(7303):213-6 (2010) PMID 20613837

The proton is the primary building block of the visible Universe, but many of its properties-such as its charge radius and its anomalous magnetic moment-are not well understood. The root-mean-square charge radius, r(p), has been determined with an accuracy of 2 per cent (at best) by electron-proton scattering experiments. The present most accurate value of r(p) (with an uncertainty of 1 per cent) is given by the CODATA compilation of physical constants. This value is based mainly on precision spectroscopy of atomic hydrogen and calculations of bound-state quantum electrodynamics (QED; refs 8, 9). The accuracy of r(p) as deduced from electron-proton scattering limits the testing of bound-state QED in atomic hydrogen as well as the determination of the Rydberg constant (currently the most accurately measured fundamental physical constant). An attractive means to improve the accuracy in the measurement of r(p) is provided by muonic hydrogen (a proton orbited by a negative muon); its much smaller Bohr radius compared to ordinary atomic hydrogen causes enhancement of effects related to the finite size of the proton. In particular, the Lamb shift (the energy difference between the 2S(1/2) and 2P(1/2) states) is affected by as much as 2 per cent. Here we use pulsed laser spectroscopy to measure a muonic Lamb shift of 49,881.88(76) GHz. On the basis of present calculations of fine and hyperfine splittings and QED terms, we find r(p) = 0.84184(67) fm, which differs by 5.0 standard deviations from the CODATA value of 0.8768(69) fm. Our result implies that either the Rydberg constant has to be shifted by -110 kHz/c (4.9 standard deviations), or the calculations of the QED effects in atomic hydrogen or muonic hydrogen atoms are insufficient.

DOI: 10.1038/nature09250
Version: za2963e q8zac q8zb4 q8zce q8zdb q8zed q8zf0 q8zgf

Similar articles you may find interesting…

  1. Flow through horizontal tubes submerged in water in the absence of a pressure gradient: mechanistic considerations.

    Langmuir (2013) PMID 23627361

    We also demonstrate a faster flow under incident light, particularly at UV wavelengths, implying that proton generation may be driven by light....
  2. The Acid Pocket: A Target for Treatment in Reflux Disease?

    Am J Gastroenterol (2013) PMID 23629599

    The nadir esophageal pH of reflux observed during pH monitoring in the postprandial period is often more acidic than the concomitant intragastric pH. This paradox prompted the discovery of the "acid pocket", an area of unbuffered gastric acid that accumulates in the proximal stomach...
  3. Dissolution improvement of poorly water-soluble drug by cogrinding method using jar mill.

    Pak J Pharm Sci 26(3):495-502 (2013) PMID 23625422

    As a representative proton pump inhibitor, Lansoprazole was poorly soluble in water which caused the low oral bioavailability. The present study was carried out to enhance the dissolution of lansoprazole by cogrinding with some commonly used hydrophilic polymers (β-CD, PVP, HPMC, L-...