Reproducibility of intraocular lens decentration and tilt measurement using a clinical Purkinje meter

J Cataract Refract Surg 36(9):7 (2010) PMID 20692566

Purpose: To determine the reproducibility of intraocular lens (IOL) decentration and tilt measurements with a new Purkinje meter instrument. Setting: Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. Methods: After pupil dilation, images of pseudophakic eyes with a plate-style IOL (Akreos Adapt) were obtained using a recently developed Purkinje meter. Intraocular lens decentration and tilt were evaluated by analyzing the captured images using a semiobjective method by marking the reflexes in the images and automatic calculation using a dedicated software program. In study 1, examiner 1 examined the eyes first followed by examiner 2. Ten minutes later, examiner 1 performed a second measurement, after which the intraexaminer and interexaminer reproducibility were determined. In study 2, a Purkinje meter was used to measure pseudophakic eyes with slitlamp finding of clinical IOL decentration, IOL tilt, or both. The results were compared with retroillumination photographs and slitlamp findings. Results: In study 1, there was high intraexaminer reproducibility for decentration (r = 0.95) and tilt (r = 0.85) and high interexaminer reproducibility for decentration (r = 0.84) and tilt (r = 0.75). In study 2, even in extreme cases of decentration and/or tilt, the Purkinje meter measurements were possible and appeared to correlate well with slitlamp findings. Conclusions: Acquisition of images in pseudophakic eyes with the Purkinje meter was simple and rapid. The method was highly reliable for 1 examiner and between 2 examiners. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.

Copyright © 2010 Elsevier Ltd. All rights reserved.

DOI: 10.1016/j.jcrs.2010.03.043
Version: za2963e q8zac q8zba q8zca q8zdc q8ze7 q8zfc q8zg3

Similar articles you may find interesting…

  1. Optical aberrations and alignment of the eye with age.

    J Vis 10(14) (2010) PMID 21196516

  2. Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations.

    J Opt Soc Am A Opt Image Sci Vis 27(11):A48-55 (2010) PMID 21045890

    A binocular adaptive optics visual simulator has been devised for the study of stereopsis and of binocular vision in general. The apparatus is capable of manipulating the aberrations of each eye separately while subjects perform visual tests. The correcting device is a liquid-crystal-on-silicon spat...
  3. Hybrid adaptive-optics visual simulator.

    Audio, Transactions of the IRE Professiona... 35(2):196-8 (2010) PMID 20081966

    We have developed a hybrid adaptive-optics visual simulator (HAOVS), combining two different phase-manipulation technologies: an optically addressed liquid-crystal phase modulator, relatively slow but capable of producing abrupt or discontinuous phase profiles; and a membrane deformable mirror, rest...