Advanced search×

Development of a second generation anti-Mullerian hormone (AMH) ELISA

J Immunol Methods 362(1-2):9 (2010) PMID 20801125

AMH is a glycoprotein dimer composed of two 72kDa monomers linked by disulfide bridges. It belongs to the transforming growth factor-@b family. AMH performs various physiological functions. In males, AMH is secreted by the Sertoli cells of the testis. During embryonic development, AMH is responsible for Mullerian duct regression. AMH continues to be produced by the testicles until puberty and then decreases slowly to residual post-puberty values. In females, AMH is produced in small amounts by ovarian granulosa cells after birth, until menopause, and then becomes undetectable. A two-step, sandwich-type enzymatic microplate assay has been developed to measure AMH levels in 20@mL of sample in less than 3h. AMH calibrators range from 0.2 to 28ng/mL. The antibodies used in the assay bind to the mature region of AMH, which is more stable to proteolysis compared to prohormone region. The AMH Gen II assay (Beckman Coulter, Inc., Webster, Texas) was standardized to the Immunotech (IOT, Beckman Coulter, Inc., Marseilles, France) AMH assay. AMH Gen II, when compared to IOT using 120 serum samples in the range of 0-20.4ng/mL yielded a correlation coefficient of 0.98 and a slope of 1.0. Total imprecision, calculated on four samples over 40 runs, four replicates per run, between two lots using CLSI EP5-A guidelines, was 5.7% at 3.8ng/mL, 7.7% at 4.4ng/mL, 5.8% at 14ng/mL and 5.3% at 16.4ng/mL. The average analytical sensitivity calculated by the interpolation of the mean plus two standard deviations of 16 replicates of the zero calibrator on two independent lots was 0.08ng/mL. Dilution and spiking studies showed an average recovery of 91-110%. Lot-to-lot comparison of two independent lots testing 38 serum samples (1.5-33ng/mL range) yielded a slope of 1.01, intercept of -0.08ng/mL and r of 0.99. When potential interferents (hemoglobin, triglycerides, and bilirubin) were added at two times the physiological concentrations, AMH concentrations were within +/-10% of the control. A highly specific and reproducible microplate AMH Gen II assay has been developed to standardize the measurement of AMH between methods. The performance of the AMH Gen II assay is ideal for investigation into the physiologic roles of AMH in men and women.

DOI: 10.1016/j.jim.2010.08.011
Version: za2963e q8za6 q8zbc q8zce q8zd6 q8zee q8zfd q8zgf

Similar articles you may find interesting…

  1. Mid-rapidity anti-baryon to baryon ratios in pp collisions at sqrt(s) = 0.9, 2.76 and 7 TeV measured by ALICE

    arXiv:1305.1562 [nucl-ex] 7 May 2013

    The ratios of yields of anti-baryons to baryons probes the mechanisms of baryon-number transport. Results for anti-p/p, anti-\Lambda/\Lambda, anti-\Xi+/\Xi- and anti-\Omega+/\Omega- in pp collisions at sqrt(s) = 0.9, 2.76 and 7TeV, measured with the ALICE detector at the LHC, are reported. Within t...
  2. Optimizing conditions of polysaccharide extraction from Shiitake mushroom using response surface methodology and its regulating lipid metabo...

    Carbohydr Polym 95(2):644-8 (2013) PMID 23648024

    Process conditions (extraction time, extraction temperature, water/solid ratio and incubation time) of Shiitake mushroom polysaccharides (SMP) were optimized by conducting experiments at three different levels using the response surface method (RSM). A second-order polynomial respons...
  3. Anti-inflammatory cytokines, pro-fibrogenic chemokines and persistence of acute HCV infection.

    J Viral Hepat 20(6):404-13 (2013) PMID 23647957

    We compared them in at-risk subjects followed prospectively for HCV infection. Levels were compared over time in subjects who controlled HCV infection (Clearance) and subjects who developed persistent HCV infection (Persistence) at two time points during acute infection: (i) first viraemic sample (i...