Advanced search×

Screening for proteinuria in cats using a conventional dipstick test after removal of cauxin from urine with a Lens culinaris agglutinin lectin tip.

Vet J 189(3):312-7 (2011) PMID 20920865

Proteinuria is an important indicator of urinary tract disease and urine dipsticks are simple and sensitive tools to screen for this marker. However, the use of dipsticks to screen for proteinuria may not be appropriate in cats, since cauxin, a 70 kDa glycoprotein, is secreted by the kidneys in clinically normal animals of this species. To circumvent this problem, a Lens culinaris agglutinin (LCA) lectin tip was developed to remove cauxin from feline urine, followed by conventional urine dipstick testing for proteinuria. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) with Coomassie brilliant blue R-250 staining indicated that >90% cauxin in the urine of 13 clinically normal cats was trapped by the LCA lectin tip, so that the dipstick protein 'score' changed from 'positive' (≥30 mg/dL) for untreated urine to 'negative' (≤10 mg/dL) for lectin tip-treated urine. In contrast, SDS-PAGE indicated that lectin tip-treated samples from 20 animals with renal disease contained high concentrations of albumin and low-molecular weight proteins; dipstick testing of lectin tip-treated urine resulted in a consistently positive protein score. The accuracy of the dipstick method for detecting cats with abnormal proteinuria is enhanced if dipsticks are used with urine samples that have first been passed through the LCA lectin tip.

Copyright © 2010 Elsevier Ltd. All rights reserved.

DOI: 10.1016/j.tvjl.2010.08.010
Version: za2963e q8zaf q8zbb q8zc0 q8zdb q8zed q8zf2 q8zge

Similar articles you may find interesting…

  1. Proteinuria: accuracy and precision of laboratory diagnosis by dip-stick analysis.

    Clin Chem 24(11):1934-9 (1978) PMID 709825

    We studied and compared results of two urine dip-stick procedures for protein with those of quantitative measurements of total protein and albumin in urine. Sensitivity, specificity, and predictive value of "normal" and "abnormal" dip-stick results, assay efficiency, technologist precision, and meth...
  2. Accuracy and precision of urinary pH determinations using two commercially available dipsticks.

    Am J Clin Pathol 70(3):368-74 (1978) PMID 30274

    The accuracy and precision of urinary pH determinations using commercially available dipsticks were studied. Two products were evaluated by 17 MT(ASCP) technologists over the pH range 4.5 to 9.0. The study included accuracy, reproducibility, variation among technologists, and variation between produ...
  3. Agreement between two methods for measuring urine pH in cats and dogs.

    J Am Vet Med Assoc 213(7):996-8 (1998) PMID 9776996

    Mean difference (+/- 2 SD) between the 2 methods was 0.1 +/- 0.9 pH units. Only 65 of 164 (40%) samples measured by use of a dipstrip were within 0.25 pH units of results obtained by use of the pH meter. CLINICAL IMPLICATIONS: When an accurate measurement of urine pH is critical for clinical decisio...