Advanced search×

Universal and specific quantitative detection of botulinum neurotoxin genes

BMC Microbiol 10(1):267 (2010) PMID 20961439

Clostridium botulinum, an obligate anaerobic spore-forming bacterium, produces seven antigenic variants of botulinum toxin that are distinguished serologically and termed "serotypes". Botulinum toxin blocks the release of acetylcholine at neuromuscular junctions resulting in flaccid paralysis. The potential lethality of the disease warrants a fast and accurate means of diagnosing suspected instances of food contamination or human intoxication. Currently, the Food and Drug Administration (FDA)-accepted assay to detect and type botulinum neurotoxins (BoNTs) is the mouse protection bioassay. While specific and sensitive, this assay requires the use of laboratory animals, may take up to four days to achieve a diagnosis, and is unsuitable for high-throughput analysis. We report here a two-step PCR assay that identifies all toxin types, that achieves the specificity of the mouse bioassay while surpassing it in equivalent sensitivity, that has capability for high-throughput analysis, and that provides quantitative results within hours. The first step of our assay consists of a conventional PCR that detects the presence of C. botulinum regardless of the neurotoxin type. The second step uses quantitative PCR (qPCR) technology to determine the specific serotype of the neurotoxin.

DOI: 10.1186/1471-2180-10-267
Version: za2963e q8za5 q8zb1 q8zca q8zd8 q8ze0 q8zfc q8zgd

Similar articles you may find interesting…

  1. Trends in the medical management of patients with heart failure.

    J Clin Med Res 5(3):194-204 (2013) PMID 23671545

    We reviewed the medical records of 9,748 residents of the Worcester, MA, metropolitan area who were hospitalized with ADHF at all 11 central Massachusetts medical centers in 1995, 2000, 2002, and 2004. Between 1995 and 2004, respectively, the prescription upon hospital discharge of b...
  2. Magnetic particle-based time-resolved fluoroimmunoassay for the simultaneous determination of α-fetoprotein and the free β-subunit of human ...

    Analyst (2013) PMID 23671904

    These results demonstrate the feasibility and potential of the new method as a rapid and highly sensitive immunoassay that could be developed into a platform for multi-analyte determinations in clinical practice....
  3. Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS...

    Analyst (2013) PMID 23671909

    We found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accurac...