Advanced search×

Plasma cluster ions decrease the antigenicity of mite allergens and suppress atopic dermatitis in NC/Nga mice.

Arch Dermatol Res 303(5):367-70 (2011) PMID 21082320

Mite antigens play important roles in the pathogenesis of atopic dermatitis (AD). We recently developed a novel air cleaner (KC-850U) using charged plasma cluster ions to eliminate a variety of allergens from house environments. The present work demonstrates the ability of KC-850U to decrease the symptoms of AD induced by mite allergens. Pooled sera from the conventional NC/Nga mice, and AD model animals, were incubated with varying concentrations of the control and KC-850U-pretreated allergens extracted from mite. The incubated mixtures were transferred to wells coated with intact allergens and subjected to ELISA to measure the amounts of immunoglobulin E (IgE) bound to the wells. Kinetic analysis revealed that exposure of mite extracts to plasma cluster ions destructed about 95% of the epitopes of the allergens. The specific pathogen-free and conventional mice were housed in rooms equipped with either KC-850U or a standard air cleaner and observed their dermal symptom for 2 weeks. Dermatological examination revealed the AD symptom of the conventional mice housed in a room equipped with an air cleaner. In contrast, the symptoms which became apparent during the experiments were suppressed remarkably exposing mice to plasma cluster ions. These observations suggested that plasma cluster ions generated by KC-850U destroyed the epitopes of mite allergens and suppressed the symptoms of AD in the mice.

DOI: 10.1007/s00403-010-1095-7
Version: za2963e q8zaf q8zbd q8zce q8zdb q8zeb q8zf9 q8zgd

Similar articles you may find interesting…

  1. Fuel consumption and CO2/pollutant emissions of mobile air conditioning at fleet level - new data and model comparison.

    Environ Sci Technol 44(13):5277-82 (2010) PMID 20527915

    Mobile air conditioning (MAC) systems are the second-largest energy consumers in cars after driving itself. While different measurement series are available to illustrate their behavior in hot ambient conditions, little data are available for lower temperatures. There are also no data available on d...
  2. Inadequate ventilation for nosocomial tuberculosis prevention in public hospitals in Central Thailand.

    Int J Tuberc Lung Dis 13(4):454-9 (2009) PMID 19335950

    Indoor ventilation rates were inadequate in almost half of the studied areas (144/323, 44.6%). The inadequacy was particularly serious in the emergency rooms (ERs) and radiological areas, where 73.8% (31/42 each) of the rooms had ACH below the recommended standards. Detailed analysis showed that mos...
  3. Health care-acquired aspergillosis and air conditioning systems.

    J Prev Med Hyg 50(1):3-8 (2009) PMID 19771754