Hand-held plasma isolation device for point-of-care testing.

IEEE Trans Biomed Eng 58(3):759-62 (2011) PMID 21118761

The ability to analyze a whole blood sample retrieved from a patient is a critical tool used for diagnosing many diseases and conditions. Real-time blood analyzers are already widely used in point-of-care diagnoses and treatment. Being able to analyze plasma that has been isolated from its whole blood source is another important diagnostic tool that has not yet been applied to point-of-care applications. Advancing plasma separation techniques to the extent that they can be integrated into a point-of-care device could expedite certain diagnostic decisions and treatments, increase the number and quality of diagnostic tests that can be administered point-of-care, and ultimately improve patient outcomes. The hand-held plasma isolation device (HHPID) utilizes a unique array of parallel fiber glass filters within a specialized housing to produce a plasma sample from a small quantity of whole blood. This can be done at a patient's bedside without a power supply. This would negate the need to send blood samples away to a laboratory to be centrifuged; a change that could save precious hours or minutes in critical care situations. Initial testing has suggested that the quality and composition of outputted plasma from the HHPID are comparable to plasma retrieved by centrifuging. The HHPID could serve as a companion device for current real-time blood analyzers, which can be enhanced to accept either a whole blood or a plasma sample depending on the blood parameter of interest.

Version: za2963e q8za4 q8zb9 q8zcb q8zd9 q8ze6 q8zf6 q8zgd

Similar articles you may find interesting…

  1. Combined joint fusion for index and middle carpometacarpal instability in elite boxers.

    J Hand Surg Eur Vol (2013) PMID 23649012

    Isolated instability of the index and middle finger carpometacarpal joints is uncommon. An unpublished injury pattern in a consecutive series of 13 elite boxers is described, with mid-term radiological and functional results of two novel surgical treatments. All the boxers (from Aust...
  2. Accuracy of torque-limiting devices for mini-implant removal: an in vitro study.

    J Orofac Orthop (2013) PMID 23649278

    Mini-implants, due to their potential for osseointegration, are exposed to torque levels that may cause them to fracture during removal. Thus, it is advisable to control the torque levels applied during mini-implant removal. MATERIALS AND METHODS: A torque sensor with strain gauges was used to analy...
  3. Human Choroid Plexus Papilloma Cells Efficiently Transport Glucose and Vitamin C.

    J Neurochem (2013) PMID 23647458

    In vitro and in vivo studies suggest that the basolateral membrane of choroid plexus cells, which is in contact with blood vessels, is involved in the uptake of the reduced form of vitamin C, ascorbic acid, through the sodium-vitamin C cotransporter, SVCT2. Moreover, very low levels...