Quantitative shear wave ultrasound elastography: initial experience in solid breast masses.

Breast Cancer Res 12(6):R104 (2010) PMID 21122101

ABSTRACT: INTRODUCTION: Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examination. The aims of this study were (1) to determine the reproducibility of shear wave elastography and (2) to correlate the elasticity values of a series of solid breast masses with histological findings to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. METHODS: Using the Aixplorer(R) ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Two observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images of each lesion and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. RESULTS: Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of the mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers and on pairs of elastography images taken by two independent operators the intraclass correlation coefficient was 0.80. Shear wave elastography versus greyscale BI-RADS performance figures were sensitivity: 97% vs 87%, specificity: 83% vs 78%, positive predictive value (PPV): 88% vs 84%, negative predictive value (NPV): 95% vs 82% and accuracy: 91% vs 83% (Ps Exact Test). CONCLUSIONS: Shear wave elastography gives quantitative and reproducible information on solid breast lesions with diagnostic accuracy at least as good as greyscale ultrasound with BI-RADS classification.

DOI: 10.1186/bcr2787
Version: za2963e q8za1 q8zb4 q8zc7 q8zdb q8ze6 q8zf2 q8zge

Similar articles you may find interesting…

  1. Human cases of methicillin-resistant Staphylococcus aureus CC398, Finland.

    Emerg Infect Dis 16(10):1626-9 (2010) PMID 20875297

    Animals may serve as a reservoir for methicillin-resistant Staphylococcus aureus (MRSA). The MRSA lineage clonal complex (CC) 398 has been reported to be common among pigs (1-3) and has also been found among other animal species. Occupational exposure to animals has been recognized as a new risk fac...
  2. 4-D x 3-D ultrasound: real-time scan conversion, filtering, and display of displacement vectors with a motorized curvilinear transducer.

    IEEE Trans Ultrason Ferroelectr Freq Co... 57(10):2271-83 (2010) PMID 20889415

    Recent research in the field of elastography has sought to expand displacement tracking to three dimensions. Once the 3-D volumes of displacement data have been obtained, they must be scan converted so that further processing, such as inversion methods to obtain tissue elasticity, can take place in...
  3. Quantitative Assessment of Arterial Wall Biomechanical Properties Using Shear Wave Imaging

    Ultrasound Med Biol 36(10):15 (2010) PMID 20800942

    A new ultrasound-based technique is proposed to assess the arterial stiffness: the radiation force of an ultrasonic beam focused on the arterial wall induces a transient shear wave (∼10 ms) whose propagation is tracked by ultrafast imaging. The large and high-frequency content (100 to 1500 Hz) of...