Development and validation of a rapid HPLC method for the determination of five banned fat-soluble colorants in spices using a narrow-bore monolithic column

Talanta 84(2):7 (2011) PMID 21376976

This work reports a fast and simple liquid chromatographic method for the simultaneous determination of five banned fat-soluble synthetic colorants, namely Sudan I-IV and Para-Red, in spice samples. The analytes were successfully separated isocratically in less than 5min on the new narrow bore monolithic column, FastGradient^(R) Chromolith (50mmx2.0mm i.d.) using a mobile phase of 0.1% (v/v) HCOOH/acetonitrile (35/65%, v/v) at a flow rate of 1.5mLmin^-^1. All colorants were detected at 506nm. The main parameters (mobile phase composition, flow rate, injection volume) affecting the separation were studied. The proposed method was thoroughly validated in terms of linearity, LODs, precision and accuracy. The method was applied to the determination of the studied azo-dyes in various spices (paprika, chilli and mixed spice powders) after ultrasound-assisted extraction. Satisfactory recoveries, ranging from 92% to 109% were obtained.

DOI: 10.1016/j.talanta.2011.01.043
Version: za2963e q8zab q8zba q8zc3 q8zdc q8ze3 q8zfc q8zgc

Similar articles you may find interesting…

  1. Low pressure separations using automated flow and sequential injection analysis coupled to monolithic columns.

    J Chromatogr Sci 47(8):648-55 (2009) PMID 19772741

    Automation is a key demand in modern analytical chemistry. Automated analytical schemes facilitate samples handling, and enable effective processes such as dilution, extraction, derivatization, and preconcentration to be carried out. Flow (FI) and sequential injection (SI) analysis are well-establis...
  2. Retroperitoneal liposarcoma extending into the thigh.

    Am J Surg 201(5):e38-40 (2011) PMID 21545897

    The authors describe a case of a giant retroperitoneal liposarcoma that extended into the thigh along the course of the iliopsoas muscle. The tumor was successfully excised en bloc through an abdominal and a proximal thigh incision. Histopathologic examination revealed a well-differe...
  3. Calibration of gamma camera systems for a multicentre European ¹²³I-FP-CIT SPECT normal database.

    Eur J Nucl Med Mol Imaging 38(8):1529-40 (2011) PMID 21468761

    The relationship between measured and actual sSBRs was linear across all systems. Variability was observed between different manufacturers and, to a lesser extent, between cameras of the same type. The NC and AC measurements were found to underestimate systematically the actual sSBRs, while the ACSC...