Validation of the charm 3 SL3 beta-lactam test for screening raw milk in compliance with the U.S. pasteurized milk ordinance. Performance Tested Method 071002.

J AOAC Int 94(1):348-57 (2011) PMID 21391513

The Charm 3 SL3 beta-Lactam Test is a 3 min receptor-based lateral-flow Rapid One-Step Assay (ROSA) that detects the six beta-lactam drugs of concern approved for dairy cattle in the United States. The method is a biochemical formulation change of the SL3 beta-Lactam Test evaluated and approved in 2007. The Charm 3 SL3 was evaluated under the AOAC Research Institute Performance Tested Method (PTM) program following the protocol of the U.S. Food and Drug Administration, Center for Veterinary Medicine. The method was approved as PTM 071002 on May 8, 2009. The following drugs were detected in three combined lots: penicillin G at 3.8 ppb, ampicillin at 8.0 ppb, amoxicillin at 8.4 ppb, cephapirin at 20.0 ppb, ceftiofur (total metabolites) at 79 ppb, and cloxacillin at 8.6 ppb > or = 90% of the time with 95% confidence. These detection levels are lower than, but within 75% of, the U.S. Safe Level/Tolerances. Lot-to-lot repeatability was typically within 20% of these determined levels. The test kit was found to be suitable for testing thawed frozen samples. It was also found to respond with equal or better sensitivity to samples that contained incurred analytes, i.e., both the microbiologically active parent drug and its active metabolites. There were no interferences from somatic cells at 1.1 million/mL, bacterial cells at 300 000 CFU/mL, or 32 other non-beta-lactam drugs at 100 ppb. Ruggedness experiments indicated that the test procedure is robust. These results meet the fit-for-purpose approval criteria for inclusion in the National Conference for Interstate Milk Shipments milk testing program.

Version: za2963e q8za9 q8zb5 q8zc6 q8zd0 q8ze8 q8zfb q8zg2

Similar articles you may find interesting…

  1. An easy and practical method for detection and estimation of microcrystalline cellulose in pasteurized milk.

    J AOAC Int 94(2):660-3 (2011) PMID 21563704

    Microcrystalline cellulose (MCC) is suspected to be a new adulteration in pasteurized milk in China, yet an efficient method for MCC detection in dairy has not been established. This study presents a novel procedure to detect and estimate MCC in pasteurized milk using dialysis, cellulase hydrolysis,...
  2. Comparison of two post-column derivatization systems, ultraviolet irradiation and electrochemical determination, for the liquid chromatograp...

    J AOAC Int 85(2):411-6 (2002) PMID 11990027

    This study compared 2 post-column derivatization (PCD) techniques for the determination of aflatoxins B1, B2, G1, and G2 (AFB1, AFB2, AFG1, and AFG2) by fluorescence detection after liquid chromatographic separation: ultraviolet (UV) irradiation (PCD(UV)) and electrochemical bromination (PCD(EC)). P...
  3. Reprocessing and sterilization of single-use electrophysiological catheters: removal of organic carbon and protein surface residues.

    J AOAC Int 92(4):1165-73 (2009) PMID 19714986

    We examined the ability of a defined reprocessing procedure coupled with a validated sterilization protocol to remove organic carbon and protein residues from worst-case soiled EP catheters resulting in clean, sterile devices. Total organic carbon (TOC) determinations indicated that detergent residu...