Advanced search×

A novel high-throughput in vivo molecular screen for shade avoidance mutants identifies a novel phyA mutation.

J Exp Bot 62(8):2973-87 (2011) PMID 21398429 PMCID PMC3202935

The shade avoidance syndrome (SAS) allows plants to anticipate and avoid shading by neighbouring plants by initiating an elongation growth response. The phytochrome photoreceptors are able to detect a reduction in the red:far red ratio in incident light, the result of selective absorption of red and blue wavelengths by proximal vegetation. A shade-responsive luciferase reporter line (PHYB::LUC) was used to carry out a high-throughput screen to identify novel SAS mutants. The dracula 1 (dra1) mutant, that showed no avoidance of shade for the PHYB::LUC response, was the result of a mutation in the PHYA gene. Like previously characterized phyA mutants, dra1 showed a long hypocotyl in far red light and an enhanced hypocotyl elongation response to shade. However, dra1 additionally showed a long hypocotyl in red light. Since phyB levels are relatively unaffected in dra1, this gain-of-function red light phenotype strongly suggests a disruption of phyB signalling. The dra1 mutation, G773E within the phyA PAS2 domain, occurs at a residue absolutely conserved among phyA sequences. The equivalent residue in phyB is absolutely conserved as a threonine. PAS domains are structurally conserved domains involved in molecular interaction. Structural modelling of the dra1 mutation within the phyA PAS2 domain shows some similarity with the structure of the phyB PAS2 domain, suggesting that the interference with phyB signalling may be the result of non-functional mimicry. Hence, it was hypothesized that this PAS2 residue forms a key distinction between the phyA and phyB phytochrome species.

DOI: 10.1093/jxb/err062
Version: za2963e q8za1 q8zb9 q8zc9 q8zde q8ze4 q8zfd q8zg6

Similar articles you may find interesting…

  1. Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS...

    Analyst (2013) PMID 23671909

    We found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accurac...
  2. Magnetic particle-based time-resolved fluoroimmunoassay for the simultaneous determination of α-fetoprotein and the free β-subunit of human ...

    Analyst (2013) PMID 23671904

    These results demonstrate the feasibility and potential of the new method as a rapid and highly sensitive immunoassay that could be developed into a platform for multi-analyte determinations in clinical practice....
  3. A miniature condensed-phase membrane introduction mass spectrometry (CP-MIMS) probe for direct and on-line measurements of pharmaceuticals a...

    Rapid Commun Mass Spectrom 27(11):1213-21 (2013) PMID 23650034

    High-throughput, automated analytical measurements are desirable in many analytical scenarios, as are rapid sample pre-screening techniques to identify 'positive' samples for subsequent measurements using more time-consuming conventional methodologies (e.g., liquid chromatography/mas...