Advanced search×

An easy and practical method for detection and estimation of microcrystalline cellulose in pasteurized milk.

J AOAC Int 94(2):660-3 (2011) PMID 21563704

Microcrystalline cellulose (MCC) is suspected to be a new adulteration in pasteurized milk in China, yet an efficient method for MCC detection in dairy has not been established. This study presents a novel procedure to detect and estimate MCC in pasteurized milk using dialysis, cellulase hydrolysis, and a reducing sugar assay. The background value of reducing sugar was eliminated by dialysis, and cellulase activity toward MCC was stable in dialyzed milk. A criterion for MCC detection and an empirical formula for MCC estimation were summarized based on the reducing sugar variation after hydrolysis. The detection sensitivity was below 0.5 g/L. Reducing sugar distribution after cellulase-catalyzed hydrolysis was examined by HPLC, and revealed that most of the detected sugar was glucose. This paper describes a practical method for detection of MCC in pasteurized milk that might benefit dairy QC.

Version: za2963e q8za1 q8zbb q8zce q8zd7 q8ze4 q8zfe q8zgf

Similar articles you may find interesting…

  1. A label-free amplified fluorescence DNA detection based on isothermal circular strand-displacement polymerization reaction and graphene oxid...

    Analyst (2013) PMID 23671905

    A label-free fluorescent DNA biosensor has been presented based on isothermal circular strand-displacement polymerization reaction (ICSDPR) combined with graphene oxide (GO) binding. The proposed method is simple and cost-effective with a low detection limit of 4 pM, which compares f...
  2. Volatile Substance Misuse: An Updated Review of Toxicity and Treatment.

    Clin Rev Allergy Immunol (2013) PMID 23649409

    Educational campaigns and legislative actions may have led to an overall decrease in the prevalence of volatile substance misuse (VSM) in many countries; however, it is still a common practice throughout the world. Studies currently suggest that girls are misusing volatile substances...
  3. Iterative rank-order normalization of gene expression microarray data.

    BMC Bioinformatics 14(1):153 (2013) PMID 23647742

    By combining approaches from existing normalization techniques, the IRON method offers several advantages. First, IRON normalization occurs pair-wise, thereby avoiding the need for all chips to be normalized together, which can be important for large data analyses. Secondly, the technique does not r...