Advanced search×

Advanced noise reduction techniques for ultra-low phase noise optical-to-microwave division with femtosecond fiber combs.

IEEE Trans Ultrason Ferroelectr Freq Control 58(5):900-8 (2011) PMID 21622045

We report what we believe to be the lowest phase noise optical-to-microwave frequency division using fiber-based femtosecond optical frequency combs: a residual phase noise of -120 dBc/Hz at 1 Hz offset from an 11.55 GHz carrier frequency. Furthermore, we report a detailed investigation into the fundamental noise sources which affect the division process itself. Two frequency combs with quasi-identical configurations are referenced to a common ultrastable cavity laser source. To identify each of the limiting effects, we implement an ultra-low noise carrier-suppression measurement system, which avoids the detection and amplification noise of more conventional techniques. This technique suppresses these unwanted sources of noise to very low levels. In the Fourier frequency range of ∼200 Hz to 100 kHz, a feed-forward technique based on a voltage-controlled phase shifter delivers a further noise reduction of 10 dB. For lower Fourier frequencies, optical power stabilization is implemented to reduce the relative intensity noise which causes unwanted phase noise through power-to-phase conversion in the detector. We implement and compare two possible control schemes based on an acousto-optical modulator and comb pump current. We also present wideband measurements of the relative intensity noise of the fiber comb.

DOI: 10.1109/TUFFC.2011.1890
Version: za2963e q8za9 q8zbc q8zc6 q8zd9 q8ze2 q8zfe q8zgd

Similar articles you may find interesting…

  1. Chromatographic separation and detection of target analytes from complex samples using inkjet printed SERS substrates.

    Analyst (2013) PMID 23671906

    We build upon our previous work on inkjet-printed SERS substrates by using paper and polymer membranes to integrate sample cleanup and analyte separation with SERS detection. Inkjet-printed paper SERS substrates provide a highly sensitive chemical detection platform of unprecedented cost and simplic...
  2. Identification of microRNAs in Caragana intermedia by high-throughput sequencing and expression analysis of 12 microRNAs and their targets u...

    Plant Cell Rep (2013) PMID 23649877

    These results would help further understanding of miRNA regulation in response to abiotic stress in C. intermedia....
  3. Retaining cytotoxic activity of anthrapyridone CO1 against multidrug resistant cells is related to the ability to induce concomitantly apopt...

    J Pharm Pharmacol 65(6):855-67 (2013) PMID 23647679

    The effect of anthrapyridone compound CO1 retaining cytotoxic activity against multidrug resistant (MDR) tumour cells on inducing cell death of the sensitive leukaemia HL60 cell line and its MDR sublines (HL60/VINC and HL60/DOX) was examined. The effects of CO1 and th...