Advanced search×

Fatal exsanguination from hemodialysis vascular access sites.

Forensic Sci Med Pathol 8(3):259-62 (2012) PMID 22160736

Exsanguination from hemodialysis vascular sites may cause a rapid death. Due to extensive blood loss at the scene, investigators may initially suspect a homicide or suicide. We reviewed 100 deaths due to hemorrhage from hemodialysis shunt sites. The majority (81%) of these hemorrhages occurred at home and 44% subsequently died at home. Recognition of this medical complication at the scene is important to prevent the dispatch of the crime scene or homicide unit. In these instances, the common causes of kidney failure included hypertensive cardiovascular disease and diabetes mellitus. The manners of death were certified as therapeutic complication (93%), accident (5%), and suicide (2%). These fatal shunt hemorrhages are rapid and large due to their superficial subcutaneous locations and elevated shunt pressures from the arterial-venous anastamosis. The cause of death statement must include the proximate cause of death, which is usually the disease that resulted in kidney failure, if it is known.

Version: za2963e q8za9 q8zbd q8zcd q8zdc q8ze2 q8zfb q8zg7

Similar articles you may find interesting…

  1. Artificial placenta - Lung assist devices for term and preterm newborns with respiratory failure.

    Int J Artif Organs (2013) PMID 23645582

    Respiratory insufficiency is a major cause of neonatal mortality and long-term morbidity, especially in very low birth weight infants. Today, non-invasive and mechanical ventilation are commonly accepted procedures to provide respiratory support to newborns, but they can reach their...
  2. Carotid artery stenting: Patient, lesion, and procedural characteristics that increase procedural complications.

    Catheter Cardiovasc Interv (2013) PMID 23630062

    From the earliest experiences with carotid artery stenting (CAS) presumptive high risk features have included thrombus-containing lesions, heavily calcified lesions, very tortuous vessels, and near occlusions. In addition patients have been routinely excluded from CAS trials if they...
  3. Retrospective Evaluation of Safety and Effectiveness of the EXOSEAL Vascular Closure Device for Single Vascular Closure and Closure after Re...

    J Vasc Interv Radiol 24(5):698-702 (2013) PMID 23622041

    To retrospectively evaluate the safety and effectiveness of the EXOSEAL vascular closure device (VCD) for first or repeated closure after retrograde percutaneous femoral arterial access. A retrospective analysis of 417 patients (271 men; mean age, 64.1 y±12.8; age ra...